Installing Pre-Builts Manually
  • 13 Feb 2025
  • Dark
    Light
  • PDF

Installing Pre-Builts Manually

  • Dark
    Light
  • PDF

Article summary

Manual Install Process

Follow these steps to install Itential Pre-built automations manually when your Internet connection is down and not available from Itential Platform.

Download Artifact JSON File

  1. Navigate to the Pre-builts collection at Itential Automation MarketPlace.
  2. Use the slider to filter by Automation.
  3. Select the desired pre-built automation to display a description, technical details and other related information.
  4. From the pre-built, click View Repository in the left navigation menu to be redirected to where the pre-built is located in the Itential Opensource repository. For demonstration purposes, Netbox IP Address Management was randomly selected (Figure 2) as an example.

Figure 1: Itential Automation Marketplace
Figure 01
 

Figure 2: Itential Pre-Built (Example)
Figure 02
 

  1. From the pre-built in the repository, click the artifact.json to open the file.
  2. Click the download icon to save the file to your local drive.

Figure 3: Itential Opensource Repository (Example artifact.json file)
Figure 03
 

Figure 4: Download File (Example)
Figure 04

Import into Admin Essentials

  1. Navigate to Admin Essentials within Itential Platform and click the import icon in the top toolbar to open the Import dialog.

    Figure 5: Admin Essentials
    Figure 05

  2. Select "Pre-built" in the dropdown list to open the Import modal.

    Figure 6: Import Dialog
    Figure 06

  3. Select "click to browse" and navigate to the artifact.json file saved to your local drive.

    Figure 7: Browse File System
    Figure 07

  4. Select the artifact.json file you downloaded. A preview of the pre-built ReadMe will display.

    Note: There may be additional dependencies that are required. The ReadMe file for the pre-built will explain if there are additional prerequisites or requirements for the install.

  5. Click the Import button to install the pre-built and its associated artifacts. Once the pre-built is installed, it will be loaded into Itential Platform.

Figure 8: Pre-Built ReadMe
Figure 08

Troubleshooting

If Itential Platform determines a dependency is not installed, you will see a warning banner and most likely will not be allowed to install the pre-built until the prerequisite is satisfied.

Figure 9: Warning Banner
Figure 09

If you experience any issues with an Itential Pre-built, please contact the Pre-builts Team by opening a service desk ticket using the Customer Portal.


Was this article helpful?

Changing your password will log you out immediately. Use the new password to log back in.
First name must have atleast 2 characters. Numbers and special characters are not allowed.
Last name must have atleast 1 characters. Numbers and special characters are not allowed.
Enter a valid email
Enter a valid password
Your profile has been successfully updated.