Below is a list of supported notification types.

Notification Object ID Description
itenSBAdapterUnreach 1.3.6.1.4.1.47688.1.1.1.0.1 An adapter related trap indicating that a connection could not be established to the specified southbound adapter.
itenSBAdapterEstab 1.3.6.1.4.1.47688.1.1.1.0.2 An adapter related trap indicating that a connection to the specified southbound adapter has been established.
itenSBAdapterFuncErr 1.3.6.1.4.1.47688.1.1.1.0.3 An adapter related trap indicating that an error has occurred with the specified southbound adapter.
itenProngSystemRestart 1.3.6.1.4.1.47688.1.1.1.0.4 A trap indicating that Itential Automation Platform (IAP) has restarted.
itenProngSysErr 1.3.6.1.4.1.47688.1.1.1.0.5 A trap containing the contents of a critical error encountered by IAP.
itenProngAppUp 1.3.6.1.4.1.47688.1.1.1.0.6 An application related trap indicating that an application is online.
itenProngAppDown 1.3.6.1.4.1.47688.1.1.1.0.7 An application related trap indicating that an application is offline.
itenProngAppCrash 1.3.6.1.4.1.47688.1.1.1.0.8 An application related trap indicating that an application has crashed unexpectedly.
itenSBAdapterDegraded 1.3.6.1.4.1.47688.1.1.1.0.9 An adapter related trap indicating that a connection to the specified southbound adapter has become degraded.
itenSBAdapterFixed 1.3.6.1.4.1.47688.1.1.1.0.10 An adapter related trap indicating that a connection to the specified southbound adapter is no longer degraded.

Notifications may contain additional variable bindings providing detailed information about the event. These variable bindings can be used to identify specific components and error messages.

Below is a list of objects supported by each notification type.

Notification Objects Description
itenSBAdapterUnreach itenProngComponentID, itenProngAdapterIP4, itenProngAdapterPort The southbound adapter unreachable notifications contain the ID, IP and port of the unreachable instance.
itenSBAdapterEstab itenProngComponentID, itenProngAdapterIP4, itenProngAdapterPort The southbound adapter established notifications contain the ID, IP and port of the unreachable instance.
itenSBAdapterFuncErr itenProngComponentID, itenProngAdapterFunction, itenProngAdapterError The southbound adapter error notifications contain the ID and function name and error text.
itenProngSystemRestart The system restart notifications do not contain any detailed objects.
itenProngSysErr itenProngSystemError The system error notifications contain a string description of the error.
itenProngAppUp itenProngComponentID The application up notifications contain the ID of the unreachable instance.
itenProngAppDown itenProngComponentID The application down notifications contain the ID of the unreachable instance.
itenProngAppCrash itenProngComponentID The application crash notifications contain the ID of the unreachable instance.
itenSBAdapterDegraded itenProngComponentID, itenProngAdapterIP4, itenProngAdapterPort The southbound adapter degraded notifications contain the ID, IP and port of the unreachable instance.
itenSBAdapterFixed itenProngComponentID, itenProngAdapterIP4, itenProngAdapterPort The southbound adapter no longer degraded notifications contain the ID, IP and port of the unreachable instance.

Was this article helpful?

Changing your password will log you out immediately. Use the new password to log back in.
First name must have atleast 2 characters. Numbers and special characters are not allowed.
Last name must have atleast 1 characters. Numbers and special characters are not allowed.
Enter a valid email
Enter a valid password
Your profile has been successfully updated.